Only Danfoss authorized, qualified personnel are allowed to repair this equipment. Specialized training is required to perform the
activities related to repair.
2.4 Designated Use
Installing and operating a Danfoss drive not following the following preconditions is regarded as non-designated use. Danfoss does
not take any liability for non-designated use.
Danfoss drives are units intended for installation in electrical systems. They comply with the requirements of various directives and
certifications. To see all valid certifications for your product, check the product label of your product.
When the drive is installed in machinery or system, these have to comply with relevant national regulations.
In any case, the drive and its components have to be operated in accordance with all national Occupational Safety & Health regula-
tions and directives.
Operation of Danfoss drives is only allowed under observance of the respective EMC regulations.
Operation of Danfoss drives is only allowed under observance of the specifications and requirements given on the product label
and in the product-specific documentation.
Danfoss drives provide dedicated functions to support the functional safety concept for your application. Nevertheless, the drive
alone is not a sufficient safety device. Perform a risk analysis for your application and add all needed safety devices.
Only use spare parts approved and provided by Danfoss. Using other spare parts can damage the drive.
2.5 Safe Operation
The drive is not suitable as the only safety device in the system. Make sure that all needed extra monitoring and protection devices
on drives, motors, and accessories are installed according to the regional safety guidelines and accident prevention regulations.
Before activating any automatic fault reset functions or changing limit values, make sure that no dangerous situations can occur
after restart. If the autoreset function is activated, the device connected to the drive output starts automatically after an automatic
fault reset.
Keep all doors and covers closed and terminal boxes screwed on during operation of the drive and when AC or DC supply is connec-
ted.
Drive components and accessories can still be live and connected to AC or DC supply, even after the operation indicators are no
longer illuminated.