Device Parameters and Properties
IMPORTANT If there is a CS/CJ-series DeviceNet Unit in the network, disable the master
IMPORTANT Uploading cannot be performed in the EtherNet/IP Network Window for the
3-7-3

Downloading Device Parameters

Downloading Parameters to a Selected Device
function of the CS/CJ-series DeviceNet Unit, or disable I/O communications
from the DeviceNet Unit monitor window, and then do the upload. If I/O com-
munications are enabled, uploading the device parameters may fail.
Note
To upload the network configuration, refer to Uploading the Network Configu-
ration from the Actual Network (Network Upload) in 3-4-3 Adding Devices.
The following dialog box will be displayed when the above operation is per-
formed.
• Click the Yes Button to start uploading.
• Click the No Button to cancel uploading.
The following dialog box will be displayed when the parameters have been
uploaded.
NE1A-SCPU01-EIP and NE1A-SCPU02-EIP. Perform uploading in the
DeviceNet Network Window.
DeviceNet network
Refer to A-7 Function Restrictions for the NE1A-SCPU0
on functions that cannot be manipulated in the EtherNet/IP Network Window.
There are two ways to download parameters to a device: downloading to the
selected devices and downloading sequentially to all the devices in the net-
work. Either way is acceptable. Make sure, however, to download parameters
to all the devices.
This function is enabled only when the Network Configurator is online. Down-
loading parameters also requires entering the device passwords.
You can download parameters to selected devices using any of the following
methods.
EtherNet/IP network
@
Section 3-7