Programming
Name
Pulse Genera-
tor
Counter
Comparator
Multi Connec-
tor
166
Notation on
Display on the Network
Function List
Configurator Logic Editor
Pulse Genera-
tor
Counter
Comparator
Multi Connec-
tor
Screen
Outputs ON/OFF pulses on Output 1
while Input 1 is ON.
Counts the number of input signals
and turns ON Output 1 hen the count
reaches the number set in the configu-
ration data.
Compares input signals (8 max.) with
the comparison value set in the config-
uration, and turns ON Output 1 when
all the input signals match the set val-
ues.
Outputs input signals (8 max.) to out-
put signals (8 max.). The input and
output signals correspond 1:1 from 1
to 8 respectively, and are not affected
by the status of other input signals.
Section 6-3
Details