Commissioning Guidelines; What This Chapter Contains - INVT Goodrive390L Series User Manual

Lift-dedicated vfd
Table of Contents

Advertisement

Goodrive390L Series Lift-Dedicated VFD

6.1 What this chapter contains

This chapter introduces the commissioning guidelines for GD390L lift-dedicated VFD.
The commissioning process is as follows.
AM
P02.00=0
202403 (V1.0)

6 Commissioning guidelines

Figure 6-1 Commissioning procedure
Start
Power on after the wiring is
correct.
Restore to default settings
(P00.09=1)
Motor type
Set motor parameters
according to the motor
nameplate
Execute motor parameter
aututuning
SM
Set the encoder
parameters
(P20.00–P20.02)
P02.00=1
Commissioning guidelines
Set the running
command channel
(P00.01)
Set the speed
command channel
(P00.07)
Adjust maintenance
running parameters
Adjust S-curve
parameters for normal
running
Adjust comfortability
Adjust the lift leveling
accuracy
Debug the running
mode
End