Goodrive390L Series Lift-Dedicated VFD
4.3.2 Control terminal diagram
R03A
R03C
R02A
R02C
R01A
R01B R01C
Terminal
name
Used to externally provide 24V±10% power supply. Max. output current:
+24V
200mA
COM
Reference ground of +24V
Regular digital input terminal
1. Internal impedance: 3.3kΩ
2. 12–30V voltage input is acceptable.
3. Bi-direction input terminal, supporting NPN and PNP (switching through
S1–S10
the jumper J1)
4. Max. input frequency: 1kHz
5. All of them are programmable digital input terminals. Users can set the
terminal function by function code.
Open collector output
Y1, CME
1. Switch capacity: 50mA/30V
2. Output frequency range: 0–1kHz
Three programmable relay outputs.
RO1
One group of NC and NO output: RO1A: NO; RO1B: NC; RO1C: common
RO2
Two groups of NO output: RO2A, RO2C; RO3A, RO3C
RO3
Contact capacity: 3A/AC250V, 1A/DC30V
1. Input range: 0–10V or 0–20mA, set through the jumper J7 and J8
2. Input impedance: 20kΩ for voltage input or 500Ω for current input
AI1, AI2
3. Resolution: 5mV when 10V corresponds to 50Hz.
4. Error: ±1% at 25°C
PT100 interface
1. Resolution: 1°C
PT+, PT-
2. Range: -20°C–150°C
3. Detection precision: ±3°C
Simplified closed loop encoder signal interface
PA, PB
1. Applicable to 5V/12V push-pull, OC encoders
2. Response frequency: 100kHz
202403 (V1.0)
Figure 4-7 GD390L MCU board terminal arrangement
24V
COM
S1
24V
H1
S6
24V
H2
Y1
Table 4-2 GD390L control circuit terminals
S2
S3
S4
S7
S8
S9
S10
CME
COM COM
PWR
Specifications
Electrical installation
S5
COM
AI2
AI1
COM GND
GND CANH
PA
PB
PT+
485+
485-
CANL
PT-
FE
23
Need help?
Do you have a question about the Goodrive390L Series and is the answer not in the manual?
Questions and answers