Goodrive390L Series Lift-Dedicated VFD
Function
code
P04.39
Enabling IF mode for
P04.40
Current setting in IF
P04.41
mode for AM
Proportional coefficient
P04.42
in IF mode for AM
Integral coefficient in IF
P04.43
mode for AM
Starting frequency
P04.44
point for switching off
IF mode for AM 1
P04.45–
P04.49
End frequency point for
switching off IMVF
P04.50
mode for motor
P04.51–
P04.56
AM VF energy-saving
P04.57
mode selection
AM VF energy-saving
P04.58
optimization coefficient
P04.59–
P04.63
202403 (V1.0)
Name
Reserved
-
Setting range: 0–1
0: Invalid
AM 1
1: Enable
The function code is used to set the
output current when IF control is
adopted for AM 1. The value is a
percentage in relative to the rated
current of the motor.
Setting range: 0.0–200.0%
The function code is used to set the
proportional coefficient of the output
current closed-loop control when IF
control is adopted for AM 1.
Setting range: 0–5000
The function code is used to set the
integral coefficient of the output
current closed-loop control when IF
control is adopted for AM 1.
Setting range: 0–5000
Setting range: 0.00Hz–P04.50
Reserved
-
Setting range:
output frequency)
Reserved
-
Setting range: 0–2
0: Max. efficiency
1: Optimal power factor
2: Max. torque current ratio
Setting range: 25.0–400.0%
Reserved
-
Description
P04.44–P00.03
Function parameter list
Default Modify
-
0
120.0%
350
150
10.00Hz
-
(Max.
25.00
-
0
100.0%
-
-
○
○
○
○
○
-
○
-
○
○
-
165