INVT Goodrive390L Series User Manual page 163

Lift-dedicated vfd
Table of Contents

Advertisement

Goodrive390L Series Lift-Dedicated VFD
Function
code
Braking current before
P01.04
Braking time before
P01.05
P01.06
ACC/DEC mode
P01.07
P01.08
Stop mode
Starting frequency of
P01.09
DC braking for stop
P01.10
DC braking current for
P01.11
202403 (V1.0)
Name
Setting range: 0.0–50.0s
Specifies the DC braking current
before startup.
start
Setting range: 0.0–100.0%
Specifies the DC braking time before
startup.
start
Setting range: 0.00–50.00s
Specifies the speed changing mode
during start and running.
0: Linear type. The output frequency
increases or decreases linearly.
1: S curve. The output frequency
increases or decreases according to
the S curve.
Reserved
-
Specifies the stop mode.
Setting range: 0–1
0: Decelerate to stop. After the stop
command becomes valid, the VFD
decelerates to decrease the output
frequency during the set time. When
the frequency decreases to zero, the
VFD stops.
1: Coast to stop. After a stop
command takes effect, the VFD
ceases the output immediately, and
the load coasts to stop according to
mechanical inertia.
Specifies the starting frequency of DC
braking for stop.
Setting range:
output frequency)
Reserved
-
Specifies the DC braking current for
stop, that is, the DC braking energy.
stop
Setting range: 0.0–100.0% (of the
rated VFD output current)
Description
0.00Hz–P00.03
(Max.
Function parameter list
Default Modify
0.0%
0.00s
1
-
-
0
0.00Hz
-
-
0.0%
155