Using The Keypad Control Menu; Finding The Keypad Control Menu; Keypad Control Parameters M3 - Danfoss VACON NXP IP00 Operating Manual

Drive modules
Table of Contents

Advertisement

VACON® NXP IP00 Drive Modules
Operating Guide

8.4 Using the Keypad Control Menu

8.4.1 Finding the Keypad Control Menu

In the Keypad control menu, the following functions are available: selecting the control mode, editing the frequency reference, and
changing the direction of the motor.
Procedure
1.
To find the Keypad control menu, scroll down in the main menu until the location indication M3 shows on the first line of
the display.
Keypad control
2.
To go to the Keypad control menu from the main menu, push the Menu button Right.

8.4.2 Keypad Control Parameters M3

Index
Parameter
P3.1
Control place
R3.2
Keypad reference
P3.3
Direction (on keypad)
P3.4
Stop button
Danfoss A/S © 2023.09
STOP
READY
I/O term
P1
P4
Min
Max
Unit
1
3
P2.1.1
P2.1.2
Hz
0
1
0
1
Default
Cust
ID
Description
1
125
The control mode
1 = I/0 terminal
2 = Keypad (control panel)
3 = Fieldbus
0.00
123
0 = Forward
1 = Reverse
0
1
114
0 = Limited function of Stop button
1 = Stop button always enabled
AQ351737303996en-000201 / DPD00888 | 89
Using the Control Panel

Advertisement

Table of Contents
loading

Table of Contents