Danfoss VACON NXP IP00 Operating Manual page 37

Drive modules
Table of Contents

Advertisement

VACON® NXP IP00 Drive Modules
Operating Guide
Example 5
A
B
5
5
A1
3
1
1
U
V
W
dUdt
4
2
2
PE
Illustration 15: Example Installation 5
1
NFE units
2
AC chokes
3
FI13 (inverter unit)
Table 15: Cabinet Data for Installation Example 4
This installation applies to drive types:
Minimum required cabinet width:
Minimum required cabinet height:
Required weight carrying capacity:
Protection rating:
Construction:
Ventilation openings:
Danfoss A/S © 2023.09
C
D
5
5
A1
3
1
1
U
V
W
dUdt
4
2
2
PE
NXP1770 5
NXP2150 5
NXP1500 6 (12-pulse)
NXP1900 6
NXP2250 6
600 mm (Cab. A and D) + 800 mm (Cab. B and C)
(23.62 in (Cab. A and D) + 31.50 in (Cab. B and C))
2200 mm
(86.61 in)
NXP1500 6 (12-pulse): 450 kg (992.1 lb) (Cab. A and D); 540 kg (1190.5 lb) (Cab. B and C)
NXP1770 5: 450 kg (992.1 lb) (Cab. A and D); 540 kg (1190.5 lb) (Cab. B and C)
NXP1900 6: 450 kg (992.1 lb) (Cab. A and D); 540 kg (1190.5 lb) (Cab. B and C)
NXP2150 5: 480 kg (1058.2 lb) (Cab. A and D); 540 kg (1190.5 lb) (Cab. B and C)
NXP2250 6: 480 kg (1058.2 lb) (Cab. A and D); 540 kg (1190.5 lb) (Cab. B and C)
This manual applies to IP21.
According to EN60439-1
See
5.2.1 Ventilation of the
4
dU/dt filter
5
DC busbars
Cabinet.
AQ351737303996en-000201 / DPD00888 | 37
Mounting the Unit

Advertisement

Table of Contents
loading