5.5 Installation Sequence

5.5.1 Installation Sequence for FR8–FR12
Use these instructions to install the VACON
Check the following:
Environmental requirements, see
Cooling requirements, see
Cabinet requirements, see
The dimensions of the AC drive, see
Procedure
1.
FR10–FR12: Install the AC choke, see
2.
Install the power unit, see
3.
If the drive was ordered with the control unit separated from the power unit, install the control unit, see
the Control Unit,
FR8–FR12.
The VACON
NXP FR10–FR12 drive can be delivered with the control unit either integrally mounted on the power unit or
®
separated from the power unit and fixed to the mounting box. The mounting box can be installed to a sidewall or the
frame of the enclosure.
4.
Make sure that there is sufficiently free space around the AC drive for cooling, see
space is also necessary for maintenance.
5.
Continue to the grounding and cabling, see
5.5.1.1 Mounting the AC Choke, FR10–FR12
This topic gives instructions on how and where to mount the AC choke in the cabinet for VACON® NXP IP00 Drive Modules, FR10–
FR12.
NOTE! VACON® NXP IP00 Drive Modules, FR8 and FR9 does not have the external AC choke.
Procedure
1.
Mount the AC choke in the bottom part of the cabinet close to the rear wall.
In case a fuse switch is later installed, mount the AC choke somewhat to the left.
2.
Fasten the AC choke on an assembly plate or using mounting rails.
3.
If the cabinet is transported in horizontal position, install an upper support plate above the AC choke, and equip the sup-
port plate with air circulation holes.
Illustration 16: Mounting AC Choke
38 | Danfoss A/S © 2023.09
NXP IP00 Drive Modules.
®
5.1 Environmental Requirements
5.2 Cooling Requirements
5.3 Cabinet Requirements for FR8–FR12
12.3.3 List of Dimension Information
5.5.1.1 Mounting the AC Choke,
5.5.1.2 Mounting the Power Unit,
6.7 Installing the
FR10–FR12.
FR8–FR12.
5.2 Cooling
Cables.
AQ351737303996en-000201 / DPD00888
Mounting the Unit
5.5.1.3 Mounting
Requirements. Some free