1-5-6 Transfer/separation section
(1) Detaching and attaching the transfer roller unit
Procedures
1. Open the right cover 1.
2. Release two lock levers and then
remove the transfer roller unit.
3. Check or replace the transfer roller unit
and refit all the removed parts.
4. When replacing the new unit,proceed
as follows:
1)Performs maintenance mode U127
(Clear Transfer Roller Counter).
(See page1-3-67 )
2)Execute maintenance mode U410
(Halftone automatic adjustment)
(See page1-3-128 )
CAUTION:
Inserting the transfer roller unit in place
until it click in,when reattaching it.
Service Manual
Lock lever
1-5-24
Transfer roller
unit
Figure 1-5-37
Lock lever
Y118240-1