3.Turn the power switch on.
4.Enter maintenance item U952.
5.Select [Entry(USB)].
6.Select [workflow].
WorkFlowData 01 - 07
7.Select the workflow save area.
Data 1 - 8
8.Select [Execute].
*: Registers the workflow in a USB memory to the main unit.
Method: Entry
1.Select [Entry].
2.Select the workflow save area.
Data 1 - 8
3.By using the [+] [-] keys or the numeric keys, enter the maintenance number to register in the workflow.
Flow 1 - 14
4.Press the [Start] key to set the setting value.
5.Press the [Start] key.
*: Execute the maintenance items in the order of registration in the workflow.
e.g.
When inserting a USB memory the following items can be registered: commands, texts and maintenance
numbers (variable).
File format: xxx.mwf
1, SET UP, 327, 000, 927, 278
2, WARRANTY, 089, 000
3, MK-A, 127, 167, 130, 410, 251
4, EH SETUP, 411, 034, 246
Completion
Press the [Stop] key.