Method: Table (Chart A)
Automatic input of the target value
*: Usually, it adjusts here.
1.Set the specified original (P/N: AVGR14938B) on the table.
2.Enter maintenance item U411.
3.Select [Target].
4.Select [Auto].
5.Press the [Start] key.
6.Select [Table(ChartA)].
7.Press the [Start] key to read the barcode of the original chart and to start the automatic adjustment.
8.When automatic adjustment has normally completed, [OK] is displayed.
*: When the error code "1e" or "1f" is displayed during the automatic adjustment in the table scanning and the bar-
code is not read, adjust the following after manually inputting the target value.
Manual input of the target value
1.Enter the target values which are shown on the lower part of the front page of the adjustment original (P/
N: AVGR14938B) by executing the maintenance mode U425.
2.Set the specified original (P/N: AVGR14938B) on the table.
3.Enter maintenance item U411.
4.Select [Target].
5.Select [U425].
6.Press the [Start] key.
7.Select [Table(ChartA)].
8.Press the [Start] key to start Auto adjustment.
9.When automatic adjustment has normally completed, [OK] is displayed.
If the image position is shifted largely at the DP adjustment below, an error might occur when adjust-
ing it with ChartA. First, use ChartB (image position) to adjust it and then use ChartA (color).
Method: DP FU (Chart B)
*: Adjusting the first side of the DP duplex scanning
1.Set the specified original (P/N: AVGR11211F) face-up on the DP.
2.Enter maintenance item U411.
3.Select [DP FU(ChartB)].
4.Press the [Start] key to start Auto adjustment.
5.When automatic adjustment has normally completed, [OK] is displayed.
Method: DP FD (Chart B)
*: Adjusting the second side of the DP duplex scanning
1.Set the specified original (P/N: AVGR11211F) face-up on the DP.
2.Enter maintenance item U411.
3.Select [DP FD(ChartB)].
4.Press the [Start] key to start Auto adjustment.
5.When automatic adjustment has normally completed, [OK] is displayed.
Method: DP Auto Adj
1.Set A4/Letter paper.
2.Press the [Start] key to print the adjustment original.
3.Set the adjustment original output on the table and press the [Start] key.
4.Set the output adjustment original with face-up on the DP.
5.Press the [Start] key and scan the original.
6.Press the [Start] key to start the 1st side automatic adjustment.
7.Set the output adjustment original with face-down on the DP.
8.Press the [Start] key and scan the original.
9.Press the [Start] key to start the 2nd side automatic adjustment.