Error code
U01040/E01040 A DCN or other inappropriate signal was received during standby for DIS signal recep-
tion.
U01041/E01041 A DCN signal was received after transmission of a DNL (MPS or EOM) signal (between
units of our make).
U01042/E01042 A DCN signal was received after transmission of a DCS, TCF signal.
U01043/E01043 A DCN signal was received after transmission of an NSS1, NSS2 (TCF) signal (between
units of our make).
U01044/E01044 A DCN signal was received after transmission of an NSS3, TCF signal (between units of
our make).
U01045/E01045 A DCN or other inappropriate signal was received after transmission of an MPS signal.
U01046/E01046 A DCN or other inappropriate signal was received after transmission of an EOM signal.
U01047/E01047 A DCN or other inappropriate signal was received after transmission of an EOP signal.
U01048/E01048 A DCN signal was received after transmission of a PRI-EOP signal.
U01049/E01049 A DCN signal was received after transmission of a CNC signal (between units of our
make).
U01050/E01050 A DCN signal was received after transmission of a CTC signal (ECM).
U01051/E01051 A DCN signal was received after transmission of an EOR.Q signal (ECM).
U01052/E01052 A DCN signal was received after transmission of an RR signal (ECM).
U01053/E01053 A DCN signal was received after transmission of a PPS.NULL signal (ECM).
U01054/E01054 A DCN signal was received after transmission of a PPS.MPS signal (ECM).
U01055/E01055 A DCN signal was received after transmission of a PPS.EOM signal (ECM).
U01056/E01056 A DCN signal was received after transmission of a PPS.EOP signal (ECM).
U01057/E01057 A DCN signal was received after transmission of a PPS.PRI-EOP signal (ECM).
U01070/E01070 Polarity reversal was detected during handshake.
U01071/E01071 Polarity reversal was detected during message transmission.
U01072/E01072 A break in loop current was detected during transmission.
U01073/E01073 During reverse polling in V.34 mode at the receiver unit, a CM signal was not detected
when transmitting after reception.
U01080/E01080 A PIP signal was received after transmission of a PPS.NULL signal.
U01091/E01091 During transmission in V.34 mode, communication was interrupted because a PPR sig-
nal was received over 10 times even after reducing the communication speed to the min-
imum with the symbol speed maintained at the level of connection.
U01092/E01092 During transmission in V.34 mode, communication was interrupted because of an impos-
sible combination of the symbol speed and communication speed.