7.Measure the distance "D" and "E" from the top edge of black belt 1 to the bottom edge of black belt 3 on
the adjustment original at two positions.
Measurement procedure
1) Measure the distance "D" and "E" between two points as follows. (D: Measure the distance from the
leading edge to the trailing edge of black belt 3 on the adjustment original at 30mm of the left edge and
deduct A. E: Measure the distance from the leading edge to the trailing edge of black belt 3 on the
adjustment original at 180mm of the left edge and deduct C.)
2) Apply the following formula for the values obtained: (D/2+E/2)
8.Enter the value solved in "Sub Scan" using the the [+] [-] keys keys.
9.Press the [Start] key to set the setting value.
30mm
A
F
Black
belt 2
D
Service Manual
148.5mm
Black belt 1
B
COL OR SCANN ER
CHART A4
No.302K 357010
Original for adjustment (P/N: AVGR14938B)
267mm
C
E
Black belt 3
Figure 3-22
1-3-142
Leading edge
[Dist1] = (A+B+C)/3
[Dist2] = F
[Dist3] = D/2+E/2
Y118240-1