Olivetti d-Copia 3002MF plus Service Manual page 230

Multifunction digital copier
Table of Contents

Advertisement

U625
Communication settings
(Message: Set Communication)
Contents
Sets the auto redialing interval and the number of times of auto redialing.
Purpose
FAX transmission may not be available if redialing interval is short. If long, it takes much time to complete
transmission. Changes the setting to prevent the following problems.
Method
1.Press the [Start] key.
2.Select the item to set.
Interval
Times
Setting: Interval
1.By using the [+] [-] keys or the numeric keys, change the setting value.
Sets the redialing interval
2.Press the [Start] key to set the setting value.
*: [Completed] is displayed.
Setting: Times
1.By using the [+] [-] keys or the numeric keys, change the setting value.
Sets the number of times of redialing
2.Press the [Start] key to set the setting value.
*: [Completed] is displayed.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Y118240-1
Items
Sets the auto redialing interval
Sets the number of times of auto redialing
Contents
Contents
Contents
1-3-163
Setting
Initial
range
setting
1 to 9 minutes 3 min-
utes
Setting
Initial
range
setting
0 to 15 times
3 times