Codes
0e
0f
10
11
12
13
14
15
16
17
18
19
1a
1b
1c
1d
1e
1f
Y118240-1
Contents
DMA time out
Magnification error in the sub-scanning
direction
Leading edge error in the sub-scanning
direction
Trailing edge error in the sub-scanning
direction
DP skew error in the sub-scanning direc-
tion
Maintenance request error
Center line error in the main scanning
direction
DP skew error in the main scanning direc-
tion
Magnification error in the main scanning
direction
Service call error
DP paper jam error
PWB replacement error
Original error
Input gamma adjustment original error
Matrix adjustment original error
Original for the white reference correction
coefficient error
Lab value detection error
Lab value comparison error
1-3-135
Corrective action
Turn the power switch off then on,
and execute again.
1. Turn the power switch off then
on, and execute again.
2. Adjust manually.
(U065 to U067, U070 to U072)
Turn the power switch off then on,
and execute again.
1. Turn the power off and on, and
execute again.
2. Adjust manually.
(U065 to U067, U070 to U072)
Turn the power off and on, and exe-
cute again.
Set the original correctly and exe-
cute again.
-
1. Clean the contact glass and slit
glass.
2. Exchange the adjustment origi-
nal.
Set the original correctly and exe-
cute again.
Check the following and execute
again.
Is the bar code dirty?
Is the original position correct?
Is the bar code position correct?
Check the following and execute
again.
Is the acquired bar code the same?
Is the original position correct?
Is the bar code position correct?
Service Manual