U101
Primary transfer voltage adjustment
(Message: Adjust 1st Transfer Voltage Output)
Contents
Set the primary transfer control voltage
Purpose
Change setting if a failure such as faint image, etc. occurs.
Setting
1.Press the [Start] key.
2.Select the item to set.
3.By using the [+] [-] keys or the numeric keys, change the setting value.
On Timing
Off Timing
Pre On Timing
Pre Bias
Rev Bias
Bias(L)
Bias(M)
Bias (S)
4.Press the [Start] key to set the setting value.
Precautions
Test copy of the original is available by pressing the [System Menu] key as interruption copy mode when
executing this maintenance mode.
Completion
Press the [Stop] key.
*: The screen for selecting a maintenance item No. is displayed.
Service Manual
Items
On Timing setting
Off Timing setting
Pre On Timing setting
Pre Bias setting
Rev Bias setting
Bias(L) setting
Bias(M) setting
Bias (S) setting
Contents
1-3-64
Setting range
Initial
setting
-1000 to 1000
0
-1000 to 1000
-70
-1000 to 1000
0
0 to 2400
70
0 to 2400
190
100 to 2400
775
100 to 2400
915
100 to 2400
1288
Y118240-1
Data
varia-
tion
-
-
-
-
-
-
-
-