Encoder Dividing Rate for Servo Controllers

Encoder output pulses for OMNUC W-Series AC Servo Drivers can be set within a range
of 16 to 16,384 pulses/revolution by setting the encoder dividing rate. Depending on the
Controller's encoder input maximum response frequency limits, however, the maximum
numbers of revolutions are limited as shown in the following tables.
H Encoder Divider Rates (Pn201)
Parameter
Parameter
No.
name
Pn201
Encoder di-
vider rate
setting
H Encoder Divider Rates (Pn201) and Maximum Rotation Speed (r/min)
16,384 to 8,193
Model
1,831
CS1W-MC221/421(-V1)
915
C200H-MC221
CV500-MC221/421
622
366
C500-NC222
Note 1. In this table, the dividing rates are shown in the top line above the multipliers.
Note 2. For example, if operating a CS1W-MC221/421(-V1) at 5,000 r/min., set Pn201 (Encoder di-
vider rate) to 4,096 (pulses/r) maximum.
Explanation
Sets the number of output pulses from
the Servo Driver
8,192 to 4,097
4
2, 1
4
3,662
1,831
1,245
457
732
Factory
setting
1,000
4,096 to 2,049
2, 1
4
2, 1
5,000
3,662
2,490
915
1,464
1,831
Chapter 6
Unit
Setting
Restart
range
power?
Pulses/r 16 to
Yes
16,384
2,048 to 1,025
1,024 max.
4
2, 1
4
5,000
5,000
5,000
5,000
4,980
5,000
2,929
3,662
5,000
2, 1
6-13