Omron OMNUC R88D-WT15HF User Manual page 452

Table of Contents

Advertisement

Appendix
H Connection Example 10: Connecting to a SYSMAC CS1W-HCP22-V1
Customizable Counter Unit
3-phase 200/230 V AC 50/60 Hz
CS1W-HCP22-V1
Special I/O connector
Name
24-VDC power supply (for output)
Common
CCW (1.6 kΩ)
Pulse
out-
put 1
CW (1.6 kΩ)
Phase-Z LD+
Phase-Z LD–
I/O connector
24 V (for output)
Deviation counter clear*
Common (for output)
Deviation positioning completed signal*
Servo ON*
Alarm reset *
Origin proximity input signal*
CCW limit input signal*
CW limit input signal*
Common (for input)
Note 1. Incorrect signal wiring can cause damage to Units and the Servo Driver.
Note 2. Leave unused signal lines open and do not wire them.
Note 3. Use the 24-V DC power supply for command pulse signals as a dedicated power supply.
Note 4. The diode recommended for surge absorption is the ERB44-02 (Fuji Electric) or equivalent.
Note 5. Do not share the 24-V DC power supply for the break with the 24-V DC power supply for con-
trol.
* The I/O signals of the CS1W-HCP22-V1 depend on the internal memory area allocations. Change the
wiring according to the allocations.
Class-3 ground
R88D-WTj
Shell
Main circuit power supply
Power Cable
R88A-CAWj
Red
R88A-CAWjR
White
Blue
Green/
Yellow
Encoder Cable
R88A-CRWj
R88A-CRWjR
Chapter 6
Main circuit contact
Surge killer
DC reactor
R88M-Wj
6-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents