Omron OMNUC R88D-WT15HF User Manual page 464

Table of Contents

Advertisement

Appendix
Parameter
Parameter
Parame-
Parame-
name
name
ter No.
ter No.
Digit
No.
Pn408
Torque
q
0
command
d
setting
1
2
3
Pn409
Notch filter
Sets notch filter 1 frequency for torque command.
1 frequency
Pn40A
Notch filter
Sets Q value of notch filter 1.
**
1 Q value
Pn40b
Notch filter
Sets notch filter 2 frequency for torque command.
**
2
frequency
Pn40C
Notch filter
Sets Q value of notch filter 2.
**
2
Q value
Note 1. Explanation for parameters set using 5 digits.
Note 2. Explanation for parameters requiring each digit No. to be set separately.
H Sequence Parameters (From Pn500)
Parameter
Parame-
name
ter No.
Digit
No.
Pn500
Positioning
Sets the range of positioning completed output 1 (INP1).
completion
range 1
Pn501
Position
Sets the number of rotations for position lock during speed
lock rotation
control.
speed
Pn502
Rotation
Sets the number of rotations for the Servomotor rotation
speed for
detection output (TGON).
motor
rotation
detection
Pn503
Speed
Sets the allowable fluctuation (number of rotations) for the
conformity
speed conformity output (VCMP).
signal
output width
Pn504
Positioning
Sets the range for positioning completed output 2 (INP2).
completion
range 2
Pn505
Deviation
Sets the detection level for the deviation counter over alarm.
counter
overflow
level
Pn506
Brake
Sets the delay from the brake command to the Servomotor
timing 1
turning OFF.
Pn507
Brake
Sets the number of rotations for outputting the brake
command
command.
speed
Pn508
Brake
Sets the delay time from the Servomotor turning OFF to the
timing 2
brake command output.
Pn509
Momentary
Sets the time during which alarm detection is disabled when
hold time
a power failure occurs.
Explanation (See note 1.)
Name
Set-
Explanation (See note 2.)
ting
Selects
0
Notch filter 1 not used.
notch filter 1
t h filt
1
1
Notch filter 1 used for torque
function.
commands.
Not used.
0
(Do not change setting.)
Selects
0
Notch filter 2 not used.
notch filter 2
t h filt
2
1
Notch filter 2 used for torque
function.**
commands.
Not used.
0
(Do not change setting.)
Explanation (See note 1.)
Name
Set-
Explanation (See note 2.)
ting
Chapter 6
Default
Default
Unit
Unit
Setting
Setting
setting
setting
range
range
0000
---
---
2000
Hz
50 to
2000
70
x0.01
50 to 400
2000
Hz
50 to
2000
70
x0.01
50 to 400
Default
Unit
Setting
setting
tti
range
3
Com-
0 to 250
mand unit
10
r/min
0 to
10000
20
r/min
0 to
10000
10
r/min
0 to 100
3
Com-
1 to 250
mand unit
1024
x 256
1 to
command
32767
unit
0
x 10 ms
0 to 50
100
r/min
0 to
10000
50
x 10 ms
10 to 100
20
ms
20 to
1000
Restart
Restart
power?
power?
---
---
---
---
---
g
Restart
power?
?
---
---
---
---
---
---
---
---
---
---
6-23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents