Cleaning Optical Fiber Connectors Using the Cassette Cleaner
This topic describes how to clean the fiber connectors using a CLETOP cassette
cleaner.
Prerequisites
Before cleaning, inspect the fiber end face with a fiber microscope or a magnifier
to confirm the degree of fiber contamination. Clean the fiber only when it is
severely contaminated. This is because the cleaning operation itself may introduce
dust, dirt, or cause damage to the fiber.
The following procedure provides the steps to clean the fiber connectors using
cartridge type cleaners. There are several types of cartridge cleaners. The following
describes a type of CLETOP cassette cleaner.
Tools, Equipment, and Materials
The following lists the required tools, equipment and materials for cleaning optical
fiber connectors:
Issue 05 (2023-03-31)
of a connector should be less than -30 dB.) If the test result is not within the
required range, process the abnormal port.
Locate the equipment room where the port resides based on the distance
between abnormal points in the OTDR test result. Preliminarily determine the
port location, disconnect the port, and perform an OTDR test on the port that
reports alarms. Check whether the distance is consistent with that in the
previous test. If not, continue to test other ports.
After the abnormal port is found, test the port using a fiber microscope. If the
port is dirty, clean it. For details, see "Inspecting and Cleaning Optical Fiber
Connectors and Adapters".
After the port is cleaned, restore the port, and ensure that the connector is
tightened. Perform an OTDR test on the port to check whether loss and
reflection of each link and node are normal.
If the fault persists, replace the flange and perform an OTDR test on the port
that reports alarms to check whether loss and reflection of each link and
node are normal.
If the fault persists, replace the optical fiber and perform an OTDR test on the
port that reports alarms to check whether loss and reflection of each link and
node are normal.
If multiple abnormal points exist on the link, repeat steps
CLETOP cassette cleaner
Optical power meter
400X fiber microscope (A video fiber microscope is recommended.)
Copyright © Huawei Technologies Co., Ltd.
4 Hardware Installation and Parts Replacement
2
to 6.
510

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne08e

Table of Contents