Huawei NE05E Hardware Manual page 34

Table of Contents

Advertisement

HUAWEI NE05E,NE08E
Hardware Guide
Item
Front-end circuit breaker/fuse [A]
Heat dissipation mode
Airflow direction
Noise at normal temperature (acoustic
power) [dB(A)]
Switching capacity
Redundant power supply
Redundant fans
Long-term operating temperature
[°C(°F)]
Restriction on the operating
temperature variation rate [°C(°F)]
Storage temperature [°C(°F)]
Long-term operating relative humidity
[RH]
Storage relative humidity [RH]
Long-term operating altitude [m(ft.)]
Storage altitude [m(ft.)]
Table 3-18 Technical specifications of the NECMHSTA0201
Item
Cabinet installation standards
Dimensions without packaging (H x W
x D) [mm(in.)]
Chassis height [U]
Issue 05 (2023-03-31)
Copyright © Huawei Technologies Co., Ltd.
3 Hardware Description
Specification
≥ 2.5 A
Air cooling
From left to right
55 dB(A)
272 Gbit/s (Bidirectional). The
maximum allowed error is 0.01%. To
be specific, 99.99% of the line rate is
guaranteed.
1+1
If a single fan fails, the system can still
work for a short period of time at an
ambient temperature of 50°C (122°F).
-20°C to 65°C (-4°F to 149°F)
≤ 30°C/hour (54°F/hour)
–40°C to +70°C (–40°F to +158 °F)
5% to 95% RH, non-condensing
5% to 100% RH, non-condensing
≤ 4000 m (13123.2 ft.) (For the
altitude in the range of 1800 m to
4000 m [5905.44 ft. to 13123.2 ft.], the
operating temperature of the device
must decrease by 1°C [1.8°F] for every
220 m [721.78 ft.].)
< 5000 m (16404 ft.)
Specification
R01S100 Outdoor Cabinet, ETSI(21-
inch), IEC(19-inch), IMB(3U)
44.5 mm x 442 mm x 220 mm (1.75 in.
x 17.4 in. x 8.66 in.)
1 U
26

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne08e

Table of Contents