Hardware Guide
Figure 4-102 Protective caps recommended
Figure 4-103 Protective caps not recommended
Tools, Equipment, and Materials
Optical connectors should be cleaned using recommended tools, equipment and
materials.
The following provides the recommended tools, equipment and materials:
Issue 05 (2023-03-31)
NO TE
The protective caps not recommended are made of soft rubber, which are apt to absorb
dust and sundries, and difficult to clean.
Optical power meter
400X fiber microscope (A video fiber microscope is recommended.)
CLETOP cassette cleaner shown in
Cleaning solvent (Isoamylol is preferred, propyl alcohol is the next, and
alcohol or formalin is forbidden.)
Non-woven lens tissue, fiber cleaning tissue, and dustfree cloth (Non-woven
lens tissue is recommended.)
Special compressed air
Copyright © Huawei Technologies Co., Ltd.
4 Hardware Installation and Parts Replacement
Figure 4-104
503