Huawei NE05E Hardware Manual page 410

Table of Contents

Advertisement

HUAWEI NE05E,NE08E
Hardware Guide
Issue 05 (2023-03-31)
Ensure that the location where the equipment is installed is free from
microbial infestation.
There are no rodents, such as mice.
Air cleanness requirements
The air is free from explosive, electric-conductive, magnetic-conductive, or
corrosive dust.
The concentrations of mechanically active substances meet the
requirements defined in the following table.
Mechanically
Active
Substance
Suspended
dust
Deposited dust
Gravel
The concentrations of chemically active substances meet the
requirements defined in the following table.
Chemically
Active
Substance
SO
2
H
S
2
NO
2
HF
NH
3
Cl
2
HCl
O
3
Mechanical stress requirements
Item
Sinusoidal vibration
Copyright © Huawei Technologies Co., Ltd.
4 Hardware Installation and Parts Replacement
Concentration
3
≤ 0.4 mg/m
2
≤ 15 mg/(m
·h)
3
≤ 300 mg/m
Monthly Average Concentration
3
≤ 0.30 mg/m
3
≤ 0.10 mg/m
3
≤ 0.50 mg/m
3
≤ 0.01 mg/m
3
≤ 1.00 mg/m
3
≤ 0.10 mg/m
3
≤ 0.10 mg/m
3
≤ 0.05 mg/m
Subitem
Velocity
Acceleration
Frequency
Range
≤ 5 mm/s
2
≤ 2 m/s
● 5 Hz to 62 Hz
● 62 Hz to 200 Hz
402

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne08e

Table of Contents