AUTOMATIC CALIBRATIONS

After tips are changed the user menu will prompt you to perform a series of automatic calibrations: Autocal Tips
Calibration, Autohome XYZ, and Auto Z Calibration.
Note: Perform an Autohome XYZ before initiating automatic calibration.
Operator interaction is not required for Auto Z Stage Zero calibration.
XY and Z Tip Offset requires that the operator analyze a calibration part and
supply the system with correction values.

START AUTO Z ZERO CALIBRATION

Start Auto Z Zero Calibration sets the model liquefier tip to the Z zero location on the build sheet.
No operator interaction is required. This is also performed automatically before each job build.

START AUTO TIP CALIBRATION

Start Auto Tip Calibration allows the user to calibrate the tip-to-tip offsets in the Z direction. No operator
interaction is required.
1.
The system automatically performs this calibration as part of the tip change wizard actions.
2.
Proper calibration allows the system to toggle material tips and place the current tip at the
precise coordinate necessary to continue accurate part build.