Auto Tip-Tip Calibration (AutoCal Tip Offset) - Manual Start

Note: An Auto Tip-to-Tip Calibration must be performed if
the initial automatic calibration fails. Use this procedure to
manually initiate the calibration.
"Auto Z Stage Zero Calibration - Manual Start" on page 6-8
must be performed before running the Auto Tip-to-Tip
Calibration.
1.
Run Auto Tip-to-Tip Calibration.
A.
B.
C.
D.
E.
2.
Run
From the Main Menu select Operator Control and press Enter.
Build Job..
>Operator Control..
Modeler Status..
Maintenance..
Select Calibrate and press Enter.
Unlock Door <E>
Load/Unload MT..
Change Tips/MT..
>Calibrate..
Select AutoCal Tips and press Enter.
Set Z Stage Zero..
>AutoCal Tips <E>
Tip Offset Value..
AutoHome XYZ <E>
The system automatically calibrates the tips in the Z direction. Calibration
time is about 5 minutes. While running, the display will show:
* Tip to Tip Calibration Activity *
* Press <ESCAPE> to Abort Calibration *
At completion of the calibration, the display will show:
* Tip to Tip Calibration Activity *
* Calibration Done: Press <MENU> Key *
"XY and Z Tip Offset - Manual Start" on page
|*Tips: Model T16
|*
Support T16
| Temp Control..
| Move Head/Stage..
| Calibration Job <E>
6-9