CHAPTER 8:
8.1

General

Isolated Analog Programming (4-20mA option, PN: G+IS420), factory installed as an option, allows
operation of the
Output Voltage and Current limit can be programmed and readback through optically isolated
signals, which are isolated from all other ground references in the power supply.
8.2

Specifications

Output voltage programming accuracy
Output current programming accuracy
Output voltage programming temperature coefficient
Programming
Output current programming temperature coefficient
Inputs
Input impedance
Absolute maximum input current
Max. voltage between program inputs and supply outputs
Output voltage monitoring accuracy
Output current monitoring accuracy
Monitoring
Maximum load impedance
Outputs
Max. voltage between monitoring outputs and supply
outputs
Overall Warm-up drift / Temperature stability is equal to the unit's standard specification plus an
additional +/-0.1% of rated Voltage / Current (deviation is due to G+IS420 card).
8.3
Isolated Programming & Monitoring Connector
Control and monitoring signals are optically isolated from all other ground references in the power
supply.
Connector Technical Information:
Connector type: 618009211821, WURTH
G+IS420 ANALOG PROGRAMMING OPTION
power supply from a 4-20mA current source.
Table 8-1: G+IS420 Specifications
Figure 8–1: J1 Connector Terminals and Functions
NOTE
181
%
+/-0.8
%
+/-0.8
PPM/°C
+/-200
PPM/°C
+/-200
Ohm
50
mA
0-30
Vdc
600
%
+/-1
%
+/-1
Ohm
500
Vdc
600