TDK-Lambda G+1U 5kW User Manual page 136

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

[SOURce]:CURRent:MODE <DSC>
Function
Sets the current sequence mode.
Parameters
0|1|2, NONE|LIST|WAVE
Query
[SOURce]:CURRent:MODE?
Return
<DSC> NONE|LIST|WAVE
[SOURce]:VOLTage:EXTernal:MODE <DSC>
Function
Sets the voltage programming source: Front panel/Communication (Digital),
external voltage, or external resistor.
Parameter
0|1|2 or DIG|VOL|RES
Query
[SOURce]:VOLTage:EXTernal:MODE?
Return
<DSC> DIG|VOL|RES
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
Function
Sets a digital programming output voltage value.
Parameters
The range is limited by the power supply model, OVP, and UVP settings.
Unit
V
Query
[SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude]?;
Return
<NR2> 5-digits format
Example
:VOLT? returns the present programmed voltage level.
:VOLT? MAX and :VOLT? MIN return the maximum and minimum
programmable voltage level.
[SOURce]:VOLTage:SLEW:DOWN <NRf+>
Function
Sets a digital voltage reference down programming slew rate.
Parameters
0.0001–999.99
Unit
V/mS
Query
[SOURce]:VOLTage:SLEW:DOWN?
Return
<NR2>
Example
:VOLT:SLEW:DOWN 1 sets a digital voltage reference down programming
slew to 1V/mSec.
:VOLT:SLEW:DOWN? returns a digital voltage down programming slope
value.
:VOLT:SLEW:DOWN? MAX, and :VOLT:SLEW:DOWN? MIN return the
maximum and minimum digital voltage reference down programming slope
value.
121