TDK-Lambda G+1U 5kW User Manual page 152

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

:FOLDback
:RELay {1|2}
[:STATe] <Bool> (?)
:TTLTrg
:MODE <DSC> (?)
[:][PROGram]
:COUNter <NR1>,INFinity (?)
:LIST
:CURRent <NRf+> (?)
:DWELl <NRf+> (?)
:VOLT <NRf+> (?)
:LOAD <NR1> (?)
:STEP <DSC> (?)
:STORe <NR1>
:WAVE
:CURRent <NRf+> (?)
:TIME <NRf+> (?)
:VOLTage <NRf+> (?)
[:][SOURce]
:CURRent
:EXTernal
[:LEVel]
:SLEW:DOWN <NRf+> (?)
:SLEW:UP <NRf+> (?)
:MODE <DSC> (?)
:VOLTage
:EXTernal
[:LEVel]
:SLEW:DOWN <NRf+> (?)
:SLEW:UP <NRf+> (?)
:MODE <DSC> (?)
:PROTection
:POWer
[:LEVel] <NRf+> (?)
:STATe <Bool> (?)
[:]STATus
:OPERation
[:EVENt]?
:CONDition?
:ENABle <NR1> (?)
:QUEStionable
[:EVENt]?
:CONDition?
[:MODE] <DSC> (?)
:DELay <NRf+> (?)
LIMit
[:STATe]<Bool> (?)
:MODE <DSC> (?)
[:IMMediate]
[:AMPLitude] <NRf+> (?)
:MODE <DSC> (?)
[:IMMediate]
[:AMPLitude] <NRf+> (?)
:LEVel <NRf+> (?)
:LOW
:DELay <NRf+> (?)
:STATe <Bool> (?)
[:LEVel] <NRf+> (?)
Set operation protection mode
Set foldback delay
Set control pins status
Set output trigger mode
Set number of iterations
Set LIST output current points
Set time intervals
Set LIST output voltage points
Load stored program from memory
Set trigger depends on execution step
Store program in memory
Set WAVE output current points
Set slopes time
Set WAVE output voltage points
Enable/disable analog mode current
limit
External source of current limit control
Set the output current
Sets falling reference current slew rate
Sets rising reference current slew rate
Sets arbitrary trigger control mode
External source of voltage limit control
Set the output voltage
Sets falling reference voltage slew rate
Sets rising reference voltage slew rate
Select arbitrary control mode
Set over-voltage protection level
Set under-voltage protection delay
Set under-voltage limit or protection
mode
Set under-voltage level
Set power level in selected above mode
Set power limit mode
Returns the value of the Event register
Returns the value of the Condition
register
Enables specific bits in the Event
register
Returns the value of the Event register
Returns the value of the Condition
register
137
FLD(?)
FBD(?)
REL
{1|2}(?)
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
<NC>
PCS(?)
PC (?)
<NC>
<NC>
<NC>
PVS(?)
PV(?)
<NC>
<NC>
<NC>
OVP(?)
<NC>
UVP(?)
UVL(?)
<NC>
<NC>
SEVE?
STAT?
SENA(?)
FEVE?
FLT?

Advertisement