TDK-Lambda G+1U 5kW User Manual page 25

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

No.
Connection
2
Ground Stud
3
DC Output Busbars /
Connector
4
Remote Sense Connector
5
Reset Button
Description
PC 6-16/ 4-GF-10,16 PHOENIX CONTACT.
5kW: 1000V–1500V 3-Phase 480 and 7.5kW 3-Phase 480:
PC 5/ 4-G-7,62 PHOENIX CONTACT.
GSP10kW–15kW: DFK–PC 16/ 4-ST-10,16 PHOENIX CONTACT.
GSPL15kW 3-Phase and GSPL22.5kW 3-Phase 480:
DFK-PC 16/ 4-STF-10, 16 PHOENIX CONTACT.
GSPL22.5kW 3-Phase 208: PC 35 HC/ 4-GF-15,00 PHOENIX CONTACT.
Functional Ground connection: M3x8 SEMS screw for Half-Rack, M4x15 Stud
for Full-Rack.
1kW–5kW: 150V–600V Connector type:
GIC 2,5/ 4-G-7,62 PHOENIX CONTACT for Half-Rack models.
IPC 5/ 4-GF-7,62 PHOENIX CONTACT for Full-Rack models.
GSP10kW–15kW:
DFK-IPC 16/ 4-STF-10,16 PHOENIX CONTACT.
1kW–5kW: 10V–100V, 5kW: 1000V–1500V, 7.5kW and GSPL15kW–22.5kW:
Busbars for all models.
A Connector for remote sensing connections.
Connect to the load for regulation of the load voltage and compensation of
load wire drop.
1kW–5kW: 10V–600V: SPT-THR 1,5/ 3-H-3,5 P26 PHOENIX CONTACT.
5kW: 1000V–1500V, 7.5kW, and GSPL15kW–22.5kW:
GIC 2,5 HCV/ 3-ST-7,62.
GSP10kW–15kW: SPT-THR 1,5/ 3-H-3,5 P26 PHOENIX CONTACT.
Set default power supply settings (Factory Reset).
Refer to Table 2-6 & Table 2-7.
Firmware revision 02.105 and below:
Press and hold Reset button between 5 and 10 seconds, default
communication interface following reset is set to USB.
Firmware revision 02.106 and above:
Press and hold Reset button up to 5 seconds, default communication
interface following reset is set to USB.