Sequencer Functions; Counter; Dwell; Time - TDK-Lambda G+1U 5kW User Manual

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

0.01s ec
Tri g Ini ta ted
Tri gger Wa i t
Tri gger Event
Tri gger Del a y
0.02s
Ti me
OUTPUT
VOLTAGE
5.1.3

Sequencer Functions

5.1.3.1

Counter

Defines the number of performed iterations. The Counter can be set to 1–9999. Any number above
9999 sets the number of iterations to infinity. Counter setting is available via the communication
command [PROGram]:COUNter <NR1>|INFinity.
5.1.3.2

Dwell

Defines the time of a specific value in the LIST mode to remain in effect. Dwell range is 1mSec–36
hours, in steps of one milli-second. Dwell setting is available via the communication command
[PROGram]:LIST:DWELl <NRf+>,{<NRf+>}.
5.1.3.3

Time

Defines the time of each slope between 2 points in the WAVE mode. Time range is 1mSec–36
hours, in steps of one milli-second.
[PROGram]:WAVE:TIME <NRf+>,{<NRf+>}.
5.1.3.4

Load

Load a sequence from a memory cell, previously stored by the STOR command.
available via the Front Panel menu (refer to section 1.8) or via the communication command
[PROGram]:LOAD <NR1>.
5.1.3.5

Store

Store a sequence into a memory cell. Up to four sequences of 100 points each can be stored.
Store function
section 1.8).
0.03s
0.02s
0.03s
COUN 2
INIT:CONT 0
STEP AUTO
Figure 5–4: WAVE Mode Sequence Example
Time setting
is available via the communication command [PROGram]:STORe <NR1> (refer to
0.03s
0.02s
0.03s
is available via the communication command
141
INIT:IMM
TRIG:DEL 0.02
WAVE:TIME 0.03,0.02,0.03
WAVE:VOLT 10,10,0
Load function
is

Advertisement

Table of Contents
loading

Table of Contents