[PROGram]:LIST:VOLTage <NRf+>,{<NRf+>}
Function
Specifies output voltage points in a list.
Voltage points are separated by commas.
The function accepts up to 100 parameters.
Parameters
The range is limited by the power supply voltage programming range
(including UVP & OVP settings).
Unit
V
Query
[PROGram]:LIST:VOLTage?
Return
<NR2>,{<NR2>} 5-digits format
Example
LIST:VOLT 2.0,2.5,3.0; LIST:VOLT MAX,2.5,MIN;
A delay of ~100mSec is required after the [PROGram]:LIST:VOLTage command if long
sequences are used, before sending any additional command.
[PROGram]:LOAD <NR1>
Function
Loads a sequence from a memory previously stored by the STOR command.
Parameters
1|2|3|4
Query
[PROGram]:LOAD?
Return
<NR1> 1|2|3|4.
If any loaded sequence data has changed, but has not been stored yet, or
if no sequence is loaded, the reply is 0.
Delay of ~20mSec is required after a LOAD command, before sending any additional command.
UVL and OVP level settings clamp sequence-programmed values.
Loading an empty sequence results in error -286,"Data Load Empty".
Loading a sequence while any sequence is running, results in error -284,"Program Currently
Running".
[PROGram]:STEP <DSC>
Function
Determines if a trigger executes the whole sequence or a single step.
AUTO - When triggered, it creates waveforms consecutively, until the whole
sequence is over.
ONCE - When triggered, it executes a single step.
Parameters
ONCE|AUTO
Query
[PROGram]:STEP?
Return
<DSC> AUTO|ONCE
NOTE
NOTES
117