OUTPut:ILC[:STATe] <Bool>
Function
Enables / Disables the ILC function.
If disabled, power supply ignores the ILC pin signal (J1-19).
Parameter
0|1, OFF|ON
Query
OUTPut:ILC[:STATe]?
Return
<Bool> 0|1
OUTPut:MODE?
Query
Returns the power supply operation mode.
If power supply output is OFF, returns OFF.
If power supply output is ON, returns CV for Constant Voltage, CC for
Constant Current, or CP for Constant Power Limit.
Return
<DSC> OFF|CV|CC|CP
OUTPut:PON[:STATe] <DSC>
Function
Determines the power supply output state after the AC recovery or non-
latching (OTP, ILC, ENA, DAISY_IN) faults.
SAFE – Power supply output recovers to off state.
AUTO – Power supply output recovers to prior failure state.
Parameter
0|1, OFF|ON, SAFE|AUTO
Query
OUTPut:PON[:STATe]?
Return
<Bool> 0|1
OUTPut:PROTection:CLEar
Function
Clears latching faults (OVP, UVP, and Foldback).
An actual fault condition must be removed before the latch is cleared.
The power supply output recovery according to OUTPut:PON state.
OUTPut:PROTection:FOLDback[:MODE] <DSC>
Function
Foldback mode is used to disable the power supply output if a transition
between operation modes occurs.
Power supply turns output off after a specified delay if there is a transition
into CV mode or into CC mode. This feature is particularly useful for
protecting current or voltage sensitive loads.
Parameter
0|1|2, OFF|CC|CV
Query
OUTPut:PROTection:FOLDback[:MODE]?
Return
OFF|CC|CV