5.3.4

LIST Mode Example

VOLT:MODE LIST
LIST:VOLT 2,4,2,8,5,4
LIST:DWEL 0.5,0.5,1,1,1,1
STEP AUTO
COUN 1
TRIG:SOUR BUS
INIT:CONT OFF
INIT
*TRG
Start condition: Assume power supply output is on; Initial voltage point is 0 Volts.
Arbitrary waveforms can be easily created by using the Waveform Creator application available on
TDK-Lambda Website. Refer to Quick Start Guide documentation on TDK-Lambda Website.
Select LIST Mode Sequence
Set voltage values "2,4,2,8,5,4" Volts
Set dwell values "0.5,0.5,1,1,1,1" Seconds
Set AUTO step execution mode "AUTO"
Set list execution iterations "1"
Select BUS trigger source via communication
interface or front panel
Trigger system is enabled for a single trigger action
Trigger initialize
Trigger command
Figure 5–5: LIST Mode Example