Wave Mode Execution Via Front Panel Example - TDK-Lambda G+1U 5kW User Manual

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

5.
Set continuous trigger initialization mode: INIT:CONT ON.
6.
Initialize trigger system: INIT.
Power supply is waiting for trigger.
7.
Turn on the power supply output and send a trigger command: *TRG.
To stop execution of a running sequence, use ABORt command (refer to section 4.14).
5.3.3

WAVE Mode Execution via Front Panel Example

1.
Load a sequence from the power supply memory cell 1:
1.1.
1.2.
1.3.
2.
Select communication or front panel as a trigger source:
2.1.
2.2.
3.
Set continuous trigger initialization mode:
3.1.
3.2.
4.
Initialize trigger system:
4.1.
4.2.
4.3.
5.
Turn on the power supply output and press Current encoder to trigger the sequencer.
To stop execution of a running sequence, press the PROG button. PROG (Green) LED
illuminates, TRIG ABORT appears. Press Current encoder to abort the running sequence.
Press the PROG button. PROG (GREEN) LED illuminates.
Rotate the Voltage encoder until LOAD 1 appears.
Rotate Current encoder to select 1, 2, 3, or 4. Press Current encoder to accept. The
display blinks once to acknowledge the setting.
Rotate the Voltage encoder until TRG.IN BUS appears.
Rotate Current encoder to select BUS. Press Current encoder to accept. The display
blinks once to acknowledge the setting.
Rotate the Voltage encoder until CONT OFF appears.
Rotate Current encoder to select ON. Press Current encoder to accept. The display
blinks once to acknowledge the setting.
Rotate the Voltage encoder until TRIG INIT appears.
Press Current encoder to initialize trigger system. TRIG ABORT appears on the display,
TRIG indicator is on.
Press BACK button, Main screen appears.
Power supply is waiting for trigger.
NOTE
NOTE
145

Advertisement

Table of Contents
loading

Table of Contents