TDK-Lambda G+1U 5kW User Manual page 183

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

Error Number
Error Description
-302
"General Error"
-304
"Advanced Slave Fault"
-305
"Advance Parallel Last Slave
Missing"
-306
"Waiting for Slave Unit"
-307
"Advanced Parallel Slave
Unit General Error"
-308
"Advanced Parallel
Mismatching Units"
-309
"Memory Data Read/Write
Failure"
-310
"Booster Mode"
-350
"Queue Overflow"
301
"PV Above OVP"
302
"PV Below UVL"
304
"OVP Below PV"
306
"UVL Above PV"
307
"On During Fault"
320
"UVP Shutdown"
321
"AC Fault Shutdown"
322
"OTP Shutdown"
323
"Fold-Back Shutdown"
324
"OverVoltage Shutdown"
325
"Daisy-Chain In (SO)
Shutdown"
326
"Output-Off Shutdown"
327
"Interlock Shutdown"
328
"Enable Shutdown"
329
"Slave mode"
330
"System is powered off"
334
"Sequencer is ON"
335
"Internal Resistance is ON" An attempt to set Constant Power Mode, Analog Programming, Slew
336
"Constant Power Mode is
ON"
Error Event
Unrecoverable system error, recycle AC. If problem persists, contact
service
Advance Parallel Fault - Slave unit communication error during
operation
Advanced Parallel Last Slave unit is missing or not connected
Advanced Parallel waiting for slave unit to turn ON
Unrecoverable system error, recycle AC. If problem persists, contact
service
Advanced Parallel connected units with different voltage or current
rating
Memory fault, can't load/store data
Booster power supply reply if communication is made through
Booster USB port
Too many SYST:ERR messages are stored in error queue. Newest
messages are discarded
Attempt to program voltage above OVP setting
Attempt to program voltage below UVL setting
Attempt to set OVP below voltage setting
Attempt to set UVL above voltage setting
Attempt to turn power supply output on when a fault exists
Under-Voltage protection shutdown occurred
AC Fail shutdown occurred
Over-Temperature shutdown occurred
Fold-Back shutdown occurred
Over-Voltage protection shutdown occurred
Daisy-Chain In (Shut-Off) shutdown occurred
Output-Off occurred by front panel
Interlock shutdown occurred
Enable shutdown occurred
Cannot execute command in Slave mode
Front panel power switch turned to OFF state
An attempt to set Constant Power Mode, Analog Programming, Slew
Rate, or Internal Resistance while Sequencer is running or initialized
Rate, or Sequencer while Internal Resistance is ON
An attempt to set Internal Resistance, Analog Programming, Slew
Rate, or Sequencer while Constant Power Mode is ON
168