Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

SYSTem:PARallel?
Query
Returns the Master/Slave setting
Single, Master + # or Slave
Return
<SRD> SINGLE|MASTER+#|SLAVE
# represents the number of slave units connected.
SYSTem:PARallel:ACKNowledge
Function
Accept present parallel configuration.
SYSTem:PON:TIME?
Query
Returns the total time power supply is connected to AC & Power Switch
is ON. Max value: 2
Unit
Minutes
Return
<NR1> 4294967295
SYSTem:PON:TIME:AC?
Query
Returns the total time power supply is connected to AC. Max value: 2
1.
Unit
minutes
Return
<NR1> 4294967295
SYSTem:PRELoad[:STATe] <Bool>
Function
Enables / Disables Preload.
If disabled, preload is deactivated 5 seconds after DC output off.
Parameters
0|1, OFF|ON
Query
SYSTem:PRELoad[:STATe]?
Return
<Bool> 0|1
NOTE
32
-1