TDK-Lambda G+1U 5kW User Manual page 88

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

Hostname
A unique name for a device on a network. The default hostname is described in
It is configured as described in section 4.7.6.6.
Auto-MDIX
Power supply LAN automatically detects if a patch or crossover LAN cable is used.
Auto-Negotiate
Power supply LAN automatically adjusts
Multicast DNS
The LAN broadcasts its hostname even if no network server is present. This is useful for
connecting over simple peer-to-peer networks.
Logging In
To change power supply output or LAN settings, a user must first log in.
When the DC Power tab or LAN tab is clicked, a login box appears:
1.
Click the Login button at the bottom-left side of the web page. A window appears (refer to the
screenshot below).
The only acceptable user name is "admin". By default, the password field is empty.
2.
Click Login.
3.
The password may be set or removed on the LAN -> Users web page.
4.
LAN Reset clears the password.
its speed
to the fastest speed available.
Figure 4–10: LOGIN Button
73
section
4.7.4.5.