TDK-Lambda G+1U 5kW User Manual page 114

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

LANG <DSC>
Function
Sets the communication protocol to SCPI language.
Parameter
SCPI
RIE <Bool>
Function
Enable / Disable ILC function. If disabled, power supply ignores the ILC pin
state.
Parameters
0|1, OFF|ON
Query
RIE?
Returns
<Bool> 0|1
PVS <DSC>
Function
Set the Voltage programming source: Front Panel, External Resistor, or
External Voltage.
Parameters
0|1|2 or DIG|VOL|RES
Query
PVS?
Returns
<DSC> DIG|VOL|RES
PCS <DSC>
Function
Set the Current programming source: Front Panel, External Resistor, or External
Voltage.
Parameters
0|1|2 or DIG|VOL|RES
Query
PCS?
Returns
<DSC> DIG|VOL|RES
APR <DSC>
Function
Set the power supply analog programming & monitoring range.
Programming – 5/10 volt or 5/10kΩ.
Monitoring – 5/10 volt
Parameters
5|10
Query
APR?
Returns
<DSC> 5|10
REL1 <Bool>
Function
Set the Programmable Pin 1 state (J1.21). 0 – MOSFET ON. 1 – MOSFET OFF.
Parameter
0|1, OFF|ON
Query
REL1?
Return
<Bool> 0|1
99

Advertisement

Table of Contents
loading

Table of Contents