[SOURce]:VOLTage:SLEW:UP <NRf+>
Function
Sets a digital voltage reference up programming slew rate.
Parameters
0.0001–999.99
Unit
V/mS
Query
[SOURce]:VOLTage:SLEW:UP?
Return
<NR2>
Example
:VOLT:SLEW:UP 1 sets a digital voltage reference up programming slew to
1V/mSec.
:VOLT:SLEW:UP? returns digital voltage up programming slope value.
:VOLT:SLEW:UP? MAX and :VOLT:SLEW:UP? MIN return the maximum
and minimum digital voltage reference up programming slope value.
[SOURce]:VOLTage:MODE <DSC>
Function
Sets the voltage sequence mode.
Parameters
0|1|2, NONE|LIST|WAVE
Query
[SOURce]:VOLTage:MODE?
Return
<DSC> NONE|LIST|WAVE
[SOURce]:VOLTage:PROTection:LEVel <NRf+>
Function
Sets a voltage protection level (OVP).
Parameters
The range is limited by the OVP programming range and voltage
programmed value. Minimum setting level is about 105% of the
programmed voltage value.
Unit
V
Query
[SOURce]:VOLTage:PROTection:LEVel?
[SOURce]:VOLTage:PROTection:LEVel? MAX
[SOURce]:VOLTage:PROTection:LEVel? MIN
Return
<NR2> 5-digits format
Minimum value is limited to 5% above the actual voltage setting value
[SOURce]:VOLTage:PROTection:LOW:DELay <NRf+>
Function
Sets the time delay between UVP fault event and output disable.
Parameters
0.1–25.5|MIN|MAX. Resolution: 0.1
Note: Round input parameter to closest 100mSec step.
Unit
S
Query
[SOURce]:VOLTage:PROTection:LOW:DELay?
VOLTage:PROTection:LOW:DELay? MAX
VOLTage:PROTection:LOW:DELay? MIN
Return
<NR2>
NOTE
122