Summary of Contents for TDK-Lambda Genesys Series

  • Page 1 Series     Programmable DC Power Supplies G1.7 - 5kW in 1U 0-100V, 0-500A PARALLEL KIT INSTRUCTION MANUAL The manual covers kit options: G/P-4U-10-40V G/P-4U-60-100V G/P-4U-150-600V                            ...
  • Page 2 General Parallel kit is supplied separately from the power supply packing according to order. The usage of parallel kit is according to customer's needs. Advanced Parallel For parallel connection, refer to advanced parallel chapter in the series User Manual.  Product Safety Instructions Safety approvals are valid for single unit only.
  • Page 3: Installation Steps

    Image  Component  Quantity  M10 x 25 Hexagon Bolt, Stainless Steel  12    Plain Washer, M10, Stainless Steel  24    Helical Spring‐Lock Washer, M10, Stainless Steel  12    Hexagon Nut, M10, Stainless Steel  12    1.4.1.2 Installation Steps 1. Attach connection plates, one on each side of the power supplies, using 16 pan head screws, 16 helical spring-lock washers and 16 plain washers as illustrated in Figure 1. Connection Plate 4U ...
  • Page 4 2. Attach output bus bars plates, one on each four terminals, using 16 hexagon bolts, 32 plain washers, 16 helical spring-lock washers and 16 hexagon nuts as illustrated in Figure 2.         Output Bus Bar Plate           ...
  • Page 5: Components List

    1.4.2 G/P-4U-60-100V - Assembly Instructions for four 60V-100V units in Parallel 1.4.2.1 Components List Image  Component  Quantity    10‐32 x 5/16 Pan Head Screw, Stainless Steel  16      Helical Spring‐Lock Washer, No. 10, Stainless Steel  16    Plain Washer, No. 10, Stainless Steel  16    Connection Plate 4U  2    Output Bus Bar Plate    2    Paralleling Cable   3    M8 x 25 Hexagon Bolt, Stainless Steel  12   ...
  • Page 6 1.4.2.2 Installation Steps 1. Attach connection plates, one on each side of the power supplies, using 16 pan head screws, 16 helical spring-lock washers and 16 plain washers as illustrated in Figure 4. Connection Plate 4U   Plain Washer, No. 10, Stainless Steel    Helical Spring‐Lock Washer, No. 10, Stainless Steel    10‐32 x 5/16 Pan Head Screw, Stainless Steel    Tightening torque: 25.4‐31.7 Lbf‐inch (2.87‐3.58Nm). ...
  • Page 7 3. Connect three paralleling cables from top unit M connector to bottom unit S connector as illustrated in Figure 6.                        Paralleling Cable    Figure 6: Four 60V‐100V Units Paralleling Cable Connection  1.4.3 G/P-4U-150-600V - Assembly Instructions for four 150V-600V units in Parallel 1.4.3.1 Components List Image ...
  • Page 8 1.4.3.2 Installation Steps 1. Attach connection plates, one on each side of the power supplies, using 16 pan head screws, 16 helical spring-lock washers and 16 plain washers as illustrated in Figure 7. Connection Plate 4U   Plain Washer, No. 10, Stainless Steel        Helical Spring‐Lock Washer, No. 10, Stainless Steel    10‐32 x 5/16 Pan Head Screw, Stainless Steel ...