SYSTem:PSINk[:STATe] <Bool>
Function
Enables / Disables Power Sink.
Parameters
0|1, OFF|ON
Query
SYSTem:PSINk[:STATe]?
Return
<Bool> 0|1
1. SYSTem:PSINk[:STATe] <Bool> command is applicable for power supplies equipped with a
Power Sink module.
2. SYSTem:PSINk[:STATe]? query will always return 0 for power supplies which do not have a
Power Sink module installed.
3. Command is available for firmware revision 02.112 and above.
SYSTem:PSOK:DELay <NRf+>
Function
Set PS_OK signal delay following output ON.
Parameters
0.000–10|MIN|MAX. Resolution: 0.001
Unit
S
Query
SYSTem:PSOK:DELay?
SYSTem:PSOK:DELay? MAX
SYSTem:PSOK:DELay? MIN
Return
<NRf>
SYSTem:RANGe <DSC>
Function
Sets the power supply analog programming & monitor range.
Programming – 5/10 Volts or 5/10kΩ.
Monitoring – 5/10 Volts.
Parameters
5|10
Query
SYSTem:RANGe?
Return
<DSC> 5|10
SYSTem:RIN[:LEVel] <NRf+>
Function
Sets the internal resistance value.
Parameters
0.001...1|MIN|MAX. Resolution: 0.001
Unit
Query
SYSTem:RIN[:LEVel]?
SYSTem:RIN[:LEVel]? MAX
SYSTem:RIN[:LEVel]? MIN
Return
<NRf> "x.xxx"