TDK-Lambda G+1U 5kW User Manual page 111

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

GSAV <NR1>
Function
Refer to SAV command description.
Parameters
1,2,3,4
Returns
No reply
GPC <NR2>
Function
Refer to PC command description.
Returns
No reply
GOUT <Bool>
Function
Refer to OUT command description.
Parameter
0|1, OFF|ON
Returns
No reply
GPV <NR2>
Function
Refer to PV command description.
Returns
No reply
Model Rated Output
Voltage (V)
10
20
30
40
50
60
80
100
150
200
300
400
500
600
1000
1500
Table 4-4: Voltage Programming Range
The power supply can accept values higher by 5% than the table values. However, it is not
recommended to program the power supply above the rated values.
Minimum (V)
Maximum (V)
0
10
0
20
0
30
0
40
0
50
0
60
0
80
0
100
0
150
0
200
0
300
0
400
0
500
0
600
0
1000
0
1500