STATus:OPERation:CONDition?
Query
Returns the value of the Operational Condition Group Condition register, which is
a read-only register that holds the real-time operational status of the power
supply.
Refer to STATus:OPERation[:EVENt]? command for the complete registers list.
Returns
<NR1> 0...65535
Example
00136
STATus:OPERation:ENABle <NR1>
Function
Sets the value of the Operational Condition Group Enable register. This
register is a mask for enabling specific bits from the Condition register to
the Event register. Refer to STATus:OPERation[:EVENt]? command for the
complete list of the registers that can be masked.
Parameters
0...65535
Query
STATus:OPERation:ENABle?
Returns
<NR1> 0...65535