Internal Resistance - TDK-Lambda G+1U 5kW User Manual

Built-in lan ( 1.5), usb, rs-232 & rs-485 interfaces built-in remote isolated analog program/monitor/control interface optional interface: is420, ieee488.2 scpi (gpib), modbus tcp or ethercat
Table of Contents

Advertisement

5.4

Internal Resistance

Internal resistance function is primarily used to simulate battery voltage drop, as a response to load
current. In addition, it can be used in cases of voltage drop over long load wires.
Power supply output voltage V
multiplied by internal resistance value setting (V
Internal resistance function is enabled via the Front Panel menu (refer to section 1.8) or the
communication command SYSTem:RIN:STATe <Bool>.
Internal resistance setting range is from 0.001 to 1 ohm, in steps of 0.001 ohms. Internal resistance
setting is available via the Front Panel menu (refer to section 1.8) or the communication command
SYSTem:RIN[:LEVel] <NRf+>.
Battery
If the Internal Resistance function is enabled, the Sequencer, Constant Power Limit, Slew-Rate,
and Analog Programming functions are disabled.
If the Sequencer, Constant Power Limit, Slew-Rate, or Analog Programming functions are
enabled, the Internal Resistance function is disabled.
is set according to voltage setting minus actual load current
OUT
I
R
S
Internal
I
resistance
V
Ideal
voltage
source
Figure 5–7: Internal Resistance Circuit
NOTE
NOTE
148
=V-I×R
).
OUT
S
V
R
OUT
I
L

Advertisement

Table of Contents
loading

Table of Contents