CHAPTER 2 SPECIFICATIONS

2.1 OUTPUT RATING

GEN
MODEL
1.Rated output voltage(1*)
2.Rated output current (*2)
3.Rated output power

2.2 INPUT CHARACTERISTICS

1.Input voltage/freg. (*3)
2.Maximum
3-Phase, 200V models:
Input current
3-Phase, 400V models:
at 100% load
3.Power Factor (Typ)
4.Efficiency (*4)
5.Inrush current (*5)

2.3 CONSTANT VOLTAGE MODE

1.Max. Line regulation (*6)
2.Max. Load regulation (*7)
3.Ripple and noise (p-p , 20MHz) (*8)
4.Ripple r.m.s., 5Hz~1MHz
5.Temperature coefficient
PPM/ C
6.Temperature stability
7.Warm-up drift
8.Remote sense compensation/wire
9.
Up-prog. response time, 0~Vomax.(*9)
10.Down-prog. response time
Full load(*9)
No load(*10)
11.Transient response time
12.Hold-up time (Typ)

2.4 CONSTANT CURRENT MODE

1.Max. Line regulation (*6)
2.Max. Load regulation (*11)
3.Load regulation thermal drift
4.Ripple r.m.s. 5Hz~1MHz (*12)
5.Temperature coefficient
PPM/ C
6.Temperature stability
7.Warm-up drift

2.5 ANALOG PROGRAMMING AND MONITORING

1.Vout voltage programming
2.Iout voltage programming (*13)
3.Vout resistor programming
4.Iout resistor programming (*13
)
5.On/off control
6.Output current monitor (*13)
7.Output voltage monitor
8.Power supply OK signal
9.Parallel operation
10.Series operation
11.CV/CC indicator
12.Enable/Disable
13.Local/Remote analog control
14.Local/Remote analog indicator
8-600
16-310
20-250
10-500
8
16
20
V
10
600
310
250
A
500
4800
5000
4960
5000
W
8
10
20
V
16
3-Phase, 200V models: 170~265Vac, 47~63Hz
---
3-Phase, 400V models: 342~460Vac, 47~63Hz
22
21
22
22
A
10.5
11
11
12
0.94 @200/380Vac, rated output power.
---
%
83
84
84
86
3-Phase 200V models: Less than 50A
---
3-Phase 400V models: Less than 20A
V
10
8
16
20
---
0.01% of rated output voltage
---
0.015% of rated output voltage +5mV
mV
75
70
75
75
mV
8
8
10
10
o
O
50PPM/ C from rated output voltage, following 30 minutes warm-up.
---
0.01% of rated Vout over 8 hrs interval following 30 minutes warm-up. Constant line, load & temp.
---
Less than 0.05% of rated output voltage +2mV over 30 minutes following power on.
V
2
2
2
2
mS
30
15
50
mS
400
500
700
600
Time for output voltage to recover within 0.5% of its rated output for a load change 10~90% of rated output
current. Output set-point: 10~100%, Local sense.
mS
Less than 1mS, for models up to and including 100V. 2mS, for models above 100V.
mS
5mSec Typical. Rated output power.
8
10
16
V
20
---
0.05% of rated output current
---
0.1% of rated output current
---
Less than 0.1% of rated output current over 30 minutes following load change.
mA
1700
1600
1000
700
o
70PPM/ C from rated output current, following 30 minutes warm-up.
O
---
0.01% of rated Iout over 8hrs interval following 30 minutes warm-up. Constant line, load & temperature.
---
8~16V model: Less than +/-0.5% of rated output current over 30 minutes following power on.
20V~600V model: Less than +/-0.25% of rated output current over 30 minutes following power on.
---
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-0.5% of rated Vout.
0~100%, 0~5V or 0~10V, user selectable. Accuracy and linearity: +/-1% of rated Iout.
---
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-1% of rated Vout.
---
0~100%, 0~5/10Kohm full scale, user selectable. Accuracy and linearity: +/-1.5% of rated Iout.
---
By electrical Voltage: 0~0.6V/2~15V or dry contact, user selectable logic.
---
---
0~5V or 0~10V, user selectable. Accuracy: +/-1%.
---
0~5V or 0~10V, user selectable. Accuracy : +/-1%.
---
4~5V-OK, 0V-Fail. 500ohm series resistance.
---
Possible , up to 4 units in master/slave mode with two wires current balance connection.
---
Possible (with external diodes), up to 2 units. 600Vdc max.from chassis ground.
---
Open collector. CC mode: On, CV mode: Off. Maximum voltage : 30V, maximum sink current: 10mA
---
Dry contact. Open: Off, Short: On. Max. voltage at Enable/Disable in: 6V.
---
By electrical signal or Open/Short: 0~0.6V or short: Remote, 2~15V or open: Local.
---
Open collector. Local: Open, Remote: On. Maximum voltage: 30V, maximum sink current: 10mA.
30-170
40-125
60-85
80-65
100-50
30
40
60
80
100
170
125
85
65
50
5100
5000
5100
5200
5000
30
40
60
100
80
22
22
22
22
22
11
11
11
11
11
88
88
86
90
88
30
40
60
80
100
70
70
70
80
90
10
8
8
15
15
5
5
5
5
5
80
800
900
1000
1200
1500
30
80
40
60
100
350
180
50
120
80
10
10
300-17
400-13
500-10
150-34
200-25
150
300
400
200
34
17
13
25
5100
5000
5100
5200
150
200
300
400
22
22
22
22
11
11
11
11
88
88
88
88
150
200
300
400
120
200
200
350
70
20
45
60
5
5
5
5
50
65
100
135
2000
2500
3000
150
200
300
400
20
50
50
15
600-8.5
500
600
10
8.5
5000
5100
500
600
22
22
11
11
88
88
600
500
300
450
70
100
5
5
80
100
170
200
3000
3000
500
600
10
10