Protective Functions; Dynamic Characteristics - TDK-Lambda GENESYS 15KW User Manual

Programmable dc power supplies
Hide thumbs Also See for GENESYS 15KW:
Table of Contents

Advertisement

2.4. Protective Functions

1. OCP
2. OCP Type
3. Knee point protection
4. Short circuit protection
5. Foldback protection
6. Foldback response time
7. OVP Type
8. OVP programming accuracy
9. OVP adjustment method
10. OVP trip point
11. OVP response time
12. Max. OVP reset time
13. Output Under Voltage limit
14. Input Under Voltage protection
15. Over Temperature protection
16. Phase Loss Protection

2.5. Dynamic Characteristics

1. Up-prog. Response time, 0-Vo(
rated
full-load
2. Up-prog. Response time, 0-Vo(
rated
no load
3. Down-prog response time full-load
4. Transient response time (CV mode)
5. Time for Output Stable
6. Output fall and rise
7. Start-Up delay
V
7.5
10 12.5 20
0 ∼ 100%
%
---
Constant current
---
None, No damage at knee point operation
---
Yes
---
Output shut down when power supply changes from CV to CC mode, manual reset by front panel OUT
button or Digital Communication, user-selectable.
S
Min = 0.25/Max = 25, Default = 0.25
Settable via "FBD" command using Digital Communication command.
---
Inverter shut-down, manual reset by AC input recycle, by front panel OUT button, Remote Analog or Digital
Communication command.
%
+/- 5% of Vo(rated)
---
Adjust by front panel Voltage encoder and Digital Communication command.
V
5% to 105% of Vo(rated) and shall always be greater than 105% of the Output voltage setting.
Default = 105% of Vo(rated)
mS
Less than 10mS for Output voltage to begin to drop.
S
7 (from AC On/Off switch turn On)
---
Prevents adjusting Output voltage below limit.
Preset by the front panel or Digital Communication command.
0-95% of Vo(rated) and shall always be less than 95% of the Output voltage setting.
Raises the PS_OK signal when Vout is below limit.
Does not affect J1 Remote Analog programming.
Default = 0V.
---
Yes, power supply shutdown below AC Input low line (non-latching).
---
Unit shall shut down when internal temperature exceeds safe operating levels. (Latched in Safe-mode and
unlatched in Auto-mode).
Yes, power supply shutdown after phase-loss detection (non-latching).
V
7.5
10 12.5 20
),
mS
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
),
mS
50
50
50
50
mS
100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100
Less than 3. Time for Vo to recover to within 2% of Vo(rated) for a load change of 50 to 100% or 100 to 50%
mS
of Io(rated).
S
2 maximum, from Enable Output until Output stable (within 2% of steady-state).
---
Overshoot limited to 125% Rated Output. Voltage at No-Load, Full-Load, Resistive Load.
S
Less than 7 (without IEEE option installed)
Note: Items 2.5.1 through 2.5.7 with resistive load.
83532002 Rev H
25
30
40
50
60
80
25
30
40
50
60
80
50
50
50
50
50
50
22
100 125 150 200 250 300 400 500 600
100 125 150 200 250 300 400 500 600
50
50
50
50
50
50
50
50
50