Each Analog Loop is capable of supporting 159 AP Analog Sensors and 159 AP
Addressable Modules (with a maximum of 99 CLIP sensors and 99 CLIP addressable
modules) which can be wired as Class A, Class X, or Class B.
•
27 Ampere Power Supply.
•
Four Class A/B NACs rated at 1.7 Amperes each, which can be configured as Audible or
Visual (silenceable or non-silenceable circuits). Audibles may be steady, Temporal
Code, California Code, or March Time.
•
Indicating circuits (NACs) may be configured to provide additional auxiliary power or
resettable auxiliary power. NAC expansion using the INX-10A and INX-10ADS.
•
Fault isolators are present on all in-panel addressable loops.
•
Configurable Signal Silence Inhibit, Auto Signal Silence, Two-Stage Operation, Assisted
Walk Test.
•
Outputs for 4 Wire resettable Smoke Power Supply, Auxiliary Power Supply, and an
interface to the Mircom RTI-1 Remote Trouble Indicator.
•
RS-485 Interface for Remote Annunciators. Remote Annunciators do not occupy a node
on the network. Up to seven annunciators can be connected per node.
•
Three Level Password Protection with field settable definition which enables the installer
to determine what functions are accessible for each level of password
•
Four queues for acknowledge with Alarm ACK, Supervisory ACK, Trouble ACK, and
BLDG (Monitor) ACK LED indicators and pushbuttons.
•
Auxiliary Form-C Relay Contacts for Common Alarm, Common Supervisory, and
Common Trouble.
•
RS-232 Port for remote system printer or "CRT terminal".
•
Two Event History Logs; one for Alarm related events and one for all events.
•
Large 4 line by 20 character alphanumeric, back-lit LCD Display with user-friendly menu
system.
•
Common Controls and Indicators for System Reset, Lamp Test, Fire Drill, Signal Silence,
General Alarm, General Alarm Acknowledge, AC On, CPU Fault, and Ground Fault.
•
Two Spare configurable switches and LED Indicators.
•
16 Zone configurable LED (bi-coloured) Annunciator with slide-in labels for Zone
Description.
•
Provides drift compensation for ionization and photoelectric smoke detectors
•
Provides Signal Coding of signal circuits for easy alarm identification (code consists of 1
to 4 digits, each digit consisting of 1-15 pulses on the signal)
•
Selection for Canadian (ULC) or USA (UL) requirements for Smoke Sensor sensitivity.
•
Extensive transient protection.
•
Surface Mountable Enclosures with removable doors for easy installation and service.
•
Removable Terminal Blocks for easy wiring and service.
•
Quad Loop Adder module ALCN-792MISO for expanding addressable loops by 2; with
daughter board ALCN-792D expanding addressable loops by a total of 4.
•
The BBX-FXMNS-6000 enclosure is for the Integrated Fire and Audio consisting of a
backbox, door and middle chassis. Part of this enclosure is the vertical mount telephone
QMT-5302NV and the vertical mount paging microphone QMP-6101NV.
•
The ANC-6000 Audio Network Controller module includes ARCnet. ARCnet reduces the
wiring for audio and telephone to the ARCnet only or fiber optics (if used).
•
The RAXN-LCDG is a graphical display remote annunciator.