AC Power Troubleshooting
Phaser 7500 Printer Service Manual
Troubleshooting Reference Table
Applicable Parts
GFI, PL18.1.15
■
Power Cord, PL18.1.23
■
Main LVPS, PL18.1.11
■
Main Power Switch kit, PL18.1.24
■
Troubleshooting Procedure Table
Step Action and Questions
1
Does the GFI Breaker trip?
2
Reset the GFI Breaker.
Does the Breaker trip again?
3
Is line voltage available at GFI
Breaker terminals 1 and 2?
4
Disconnect the Power Cord.
Is line voltage available at the wall
outlet?
5
Check the Power Cord.
Is the Power Cord undamaged?
6
Unplug the Power Cord and
disconnect J1 on the Main LVPS.
Check these connections.
GFI Breaker J10 <=> Main LVPS J1-
■
1
GFI Breaker J11 <=> Main LVPS J1-
■
3
Are the circuits secure?
7
Turn the power On.
Is the voltage between the Main
LVPS J4-1 and J4-3 110V/220V?
8
Is the voltage between the Main
Power Switch P57 110V/220V?
General Troubleshooting
Wiring and Plug/Jack Map References
"Map 5 - Back Plane, GFI, TM Relay,
■
Fuser Fan" on page 10-21
Yes
No
Go to step 3.
Go to step 2.
Check AC for a
Troubleshooting
short circuit.
complete.
Go to step 6.
Go to step 4.
Go to step 5.
Advise the
customer.
Replace the
Replace the
GFI (REP 18.9,
Power Cord.
page
8-196).
Go to step 7.
Repair the
wiring.
Check the AC
Go to step 8.
circuit to each
component.
Repair
Go to step 9.
connections in
these circuits:
Power Switch
■
P57 <=>
Main LVPS
J4-1
Power Switch
■
P61 <=>
Main LVPS
J4-3
4-13